On obtaining a general building approval (abZ) for car park ceiling slabs with carbon concrete

Carbon concrete is a recent material for which carbon-fiber strands as a composite material in the form of non-metallic reinforcement are inserted in concrete and for which no long-term experience is available yet. Therefore, a profile of requirements has to be determined for the use of carbon concrete in floor slabs for parking garages; this basically includes the temperature at the level of the reinforcement layer, the intended service life, a long-term load to be expected, as well as a potential impact of the alkaline environment and possibly existing moisture in the structural component. In addition, a dynamic loading that is not stipulated as standard requirement but can quite adversely affect the bond between concrete and reinforcement. This results in an experimental concept which, in comparison to current application areas of carbon concrete (reinforcing, repairing and strengthening), moreover does not use a high-performance fine concrete, but a normal-strength concrete with a large grain of 16 mm.

An experimental concept was derived from this profile of requirements and is focusing on a so-called durability test with overlapping of the maximum possible boundary conditions. That is to say, a long-term load in at least the range of short-term strength being determined previously in an aqueous solution with a pH value of 13.7 and a test temperature being 15 K below the glass transition temperature of the impregnation material of the reinforcement. In this way, in a time-lapse testing and by means of an Arrhenius equation, it is possible to determine the strength at the time of the intended service life. Structural components in full scale, moreover, provided design values on the resistance side. A systematically structured test concept that was successfully completed and a quality assurance concept provided for the basis of a national technical approval of floor slabs for parking garages made of carbon concrete.

x

Related articles:

Issue 03/2025

Deflection limitation of concrete members with non-metallic reinforcement

In non-metallic reinforced concrete members subject to bending the limitation of deflection at the serviceability limit state (SLS) is often decisive. Consequently, the full potential of this...

more
Issue 11/2024 SOLIDIAN

Resistance of carbon reinforcement to hydrophobation

Steel-reinforced concrete is used by the construction industry all over the world. But it has one weakness: its reinforcement is subject to corrosion. To minimize this risk, it is sometimes protected...

more
Issue 02/2016 International examples

Bridges with non-metallic reinforcement

Over the last few years, the requirements on bridge structures have considerably increased owing to the growing traffic volume and they are due to become even more stringent in the years ahead. A not...

more
Issue 05/2024

Limitation of crack width in non-metallic reinforced concrete components

With the introduction of the DAfStb Guideline “Concrete members with non-metallic reinforcement”, the verification of crack width limitation is standardized for the use of non-metallic reinforcement...

more
Issue 02/2020 Digital construction

Novel carbon-fiber reinforcement for concrete 3D printing and other methods

Mineral-impregnated carbon-fiber composites (MCFs) constitute a new type of reinforcement for construction. While inheriting the advantages of existing carbon-fiber reinforcements, which are composite...

more