Load tests

Long erection spans with strengthened lattice girders

 Load tests performed on precast floor plates confirm erections spans of up to 6 m. To achieve these spans with high lattice girders, diagonals of 9-mm strength combined with upper chords of 16-mm thickness are required. Filigran-EV lattice girders were granted a technical approval for these spans.

Precast floor plates for floor systems consist of precast reinforced-concrete slabs of 5 cm thickness in which lattice girders are incorporated (Fig. 1) and an insitu concrete topping, which, when hardened, forms a structurally compo-site slab with the floor. In the erection state, the precast floor plates carry their own weight, the load imposed by the insitu concrete topping and the live load that occurs during its placement. Here, the flexurally rigid lattice girders increase the stiffness and the bearing capacity of the thin precast floor plate. The dimensions of the lattice girders, as...

Related articles:

Issue 2019-02 European product standard or German approval?

Erection state of lattice-girder floors

Lattice girders in floor plates for floor systems in the erection state of prefabricated reinforced-concrete slabs ensure their flexural strength and shear resistance as well as their bending...

more
Issue 2014-02 Increasing the bearing capacity in the vicinity of integrated service lines

Effectiveness of lattice girders –

Use of lattice girders in reinforced-concrete floor plates is a widely practiced method of construction for conventional high-rise building structures. An estimated 70?% of all floors in these...

more
Issue 2010-09 Safe Transport of 15.3 m long Filigran Slabs

Precast Plant Dobler is Manufacturing with Strengthened Filigran EV lattice girders

The engineering consultancy of  Dr. Schütz Ingineure based in Kempten selected the static system and the dimensioning. The slab was chosen to be 34 cm thick and constructed as a semi-precast slab by...

more
Issue 2017-02 Lattice girders under cyclic loading

Fatigue of semi-precast slabs

Due to the high efficiency and flexibility of semi-precast slabs with lattice girders compared to in-situ concrete structures, the use of these slab systems increase in building and industrial...

more
Issue 2014-02 Punching shear tests on precast concrete slabs lead to European Technical Approval (ETA)

With projecting loops to peak load –

Flat slabs made as precast reinforced-concrete slabs with lattice girders and an effective in-situ concrete topping prove to be cost-efficient. Nevertheless, such flat slabs – in contrast to line...